The difference between the masonry structure and the concrete structure of externally bonding carbon fiber reinfroced polymer(CFRP) sheet:Substrate difference,Material surface difference,Construction methods difference
The difference between the masonry structure and the concrete structure of externally bonding carbon fiber reinfroced polymer(CFRP) sheet:
1.Substrate difference
When the masonry structure is bonded with carbon fiber cloth, the base material is made up of two materials, brick and mortar, because masonry building is built by single brick and mortar, and the saturation of mortar can not be effectively controlled, and its integrity and quality are poor.
When the concrete structure is bonded with carbon fiber cloth, the base material is concrete, and the concrete is the engineering composite material cemented by cementitious material to aggregate. The concrete can be regarded as homogeneous and continuous material, and has good integrity.
2.Material surface difference
Masonry structure is composed of a large number of bricks and mortar piled up, the structure of the existence of a large number of mortar, mortar mortar between the full degree of inconsistency, and different block strength are not the same, no unified evaluation of its surface strength, can only be used to determine the surface strength of brick and mortar. In general, the surface strength of the masonry structure is not as good as the surface strength of the concrete structure.
High strength concrete structure surface, according to the GB50367-2013 "reinforced concrete structure design specification" set when the concrete CFRP reinforcement when the concrete surface strength of not less than C15, and the concrete surface tensile bond strength shall not be less than 1.5MPa.
3.Construction methods difference
When the masonry structure reinforced with carbon fiber, the surface defects of the masonry structure needs to be repaired, and then on the wall and column surface must first do a layer of cement mortar screeding layer, the layer thickness should not be less than 15mm and flat, the strength of cement mortar shall not be less than M10, the smooth curved layer after curing, in accordance with the method paste carbon fiber to concrete structure construction.
When the carbon fiber cloth and concrete structure, need to be polished with new reinforced concrete, loose concrete removed, clean the surface of concrete member and yang angle round process, there will be defects repaired, and then paste the carbon fiber cloth construction.
يمكنك العثور على أي شيء تحتاجه هنا ، ولديك ثقة في تجربة هذه المنتجات ، وسوف تجد الفرق الكبير بعد ذلك.
تستخدم المواد البولیمریة المسلحة بألیاف الکربون في العدید من تطبیقات الهندسة الإنشائیة کتدعیم الأعمده، الکمرات، الجدران، البلاطات و الأسقف في المنشآت و المباني
الثخانة المنخفضة لهذا الایبوکسي المخفف يجعل هذا المنتج قادراً على اختراق سطح الخرسانة في الأنابيب الشعرية وإنشاء رابطة خرسانية قوية جدًا.
لاصق الإيبوكسي متغير الانسيابية هو عبارة عن جزء من مادة لاصقة تشبب بالإيبوكسي ، وهي مادة لاصقة غير قابلة للاهتراء لتدعيم النسيج لأسلوب الاستخدام الجاف ، وراتنج التمهيدي لنظام التطبيقات الرطبة ، ولصق المواد الإنشائية لربط صفائح FRP.